POWER MEASUREMENT USING CT & PT

Home Electronics Electrical lab Trainers POWER MEASUREMENT USING CT & PT

POWER MEASUREMENT USING CT & PT

Category: Electronics

Model No:IEE-44

Power Measurement using CT & PT setup is designed to explore the measurement techniques used in electrical meters for measurement of Voltage, Current, Power etc. Current Transformer (CT) and Potential Transformer (PT) are used to sense Current and Voltage respectively from a transmission line. The various parameters that affect the Current and Voltage sensing using CT and PT are primary and secondary winding turn gauge of wire and type of core.provides in-depth explaination and experimental analysis of various configurations of Current and Voltage measurement using CT and PT. The students can measure the Voltage, Current, Wattage and Power Factor. Digital Voltmeter, Ammeter and Wattmeter are provided on panel to increase accuracy of measurement. The meters have very high accuracy and resolution.

Product Description

The various parameters that affect the Current and Voltage sensing using CT and PT are primary and secondary winding turn gauge of wire and type of core.provides in-depth explaination and experimental analysis of various configurations of Current and Voltage measurement using CT and PT.

Features:

  • Inbuilt single phase current and voltage source
  • Inbuilt Current Transformer (CT) & Potential Transformer (PT)
  • CT can be configured for various turns ratio
  • Digital meters for accurate result and analysis
  • Designed by considering all the safety standards
  • Diagrammatic representation for the ease of connections
  • Exclusive and Attractive Design: Last

Scope of Learning:

  • Study of measure high value of AC Current by a low range AC Ammeter and Current Transformer
  • Study of measure high value of AC Voltage by a low range AC Voltmeter and Potential Transformer
  • Study of Measure Power using CT & PT
  • Students can configure primary winding of CT to understand and analyse effect on secondary winding

Technical Specifications:

  • Mains Supply      :     230V ±10%, 50Hz
  • Variac
  • Input                    :     230V AC
  • Output                 :     0-270V AC
  • Current Rating     :     5A

Ammeter (2 nos.)

  •     Display Resolution     :     0.01A AC
  •     Range Min/Max         :     0.1/5A

Voltmeter (2 nos.)

  •     Display Resolution     :     1V AC
  •     Range Min/Max         :     10V/300V

Wattmeter

  •     Display Resolution     :     1W
  •     Range Min/Max         :     15/1500W

Current Transformer

  • CT Ratio         :     1:10
  • Secondary Current Rating     :     2A

Potential Transformer
Pt1

  •     Primary         :     230V
  •     Secondary    :     115V
  •     PT Ratio        :     1:2

Pt2

  •     Primary         :     230V
  •     PT Ratio       :     1:4
  •     Rheostat       :     220O, 2.8A
  •     MCB              :     2A (SPN)    

Insif Products

Our Related Product

Insif India has regular exports to the following countries: India, Afghanistan, Albania, Algeria, Andorra, Angola, Antigua and Barbuda, Argentina, Armenia, Australia, Austria, Azerbaijan, Bahamas, Bahrain, Bangladesh, Barbados, Belarus, Belgium, Belize, Benin, Bhutan, Bolivia, Bosnia and Herzegovina, Botswana, Brazil, Brunei, Bulgaria, Burkina Faso, Burma/ Myanmar, Burundi, Cambodia, Cameroon, Canada, Cape Verde, Central African Republic, Chad, Chile, Colombia, Comoros, Congo, Congo, Costa Rica, Cote d'Ivoire/Ivory Coast, Croatia, Cuba, Cyprus, Czech Republic, Denmark, Djibouti, Dominica, Dominican Republic, East Timor, Ecuador, Egypt, El Salvador, Equatorial Guinea, Eritrea, Estonia, Ethiopia (Addis Ababa), Fiji, Finland, France, Gabon, Gambia, Georgia, Germany, Ghana, Greece, Grenada, Guatemala, Guinea, Guinea-Bissau, Guyana, Haiti, Honduras, Hungary, Iceland, Indonesia, Iran, Iraq, Ireland, Israel, Italy, Jamaica, Japan, Jordan, Kazakstan, Kenya (Nairobi), Kiribati, Korea, North, Korea, South, Kuwait, Kyrgyzstan, Laos, Latvia, Lebanon, Lesotho, Liberia, Liechtenstein, Lithuania, Luxembourg, Macedonia, Madagascar, Malawi (Lilongwe), Malaysia (Kuala Lumpur), Maldives, Mali, Malta, Marshall Islands, Mauritania, Mauritius, Mexico, Micronesia, Moldova, Monaco, Mongolia, Montenegro, Morocco, Mozambique, Namibia, Nauru, Nepal, Netherlands, New Zealand, Nicaragua, Niger, Nigeria (Abuja), Norway, Oman, Palau, Panama, Papua New Guinea, Paraguay, Peru, Philippines (Manila), Poland, Portugal, Qatar, Romania, Russia, Rwanda (Kigali), Saint Kitts and Nevis, Saint Lucia, Saint Vincent and the Grenadines, Samoa, San Marino, Sao Tome and Principe, Saudi Arabia, Senegal, Serbia, Seychelles, Sierra Leone, Singapore, Slovakia, Slovenia, Solomon Islands, Somalia, South Africa, South Sudan, Spain, Sri Lanka, Sudan, Suriname, Swaziland, Sweden, Switzerland, Syria, Tajikistan, Tanzania, Thailand, Togo, Tonga, Trinidad and Tobago, Tunisia, Turkey, Turkmenistan, Tuvalu, Uganda (Kampala), Ukraine, United Arab Emirates (Dubai), United Kingdom (London), United States, Uruguay, Uzbekistan, Vanuatu, Venezuela, Vietnam, Yemen , Zambia (Lusaka), Zimbabwe